How a Ground-Plate Cyclone Dust Collector Works

The Aerodyne GPC Dust Collector operates differently. A sloped spiral inlet directs the dirty gas stream toward a fixed ground plate and hopper of the dust collector. The ground plate forces vortex reversal to occur in a much shorter space, eliminating the need for a long, tapered body. As the dirty gas stream strikes the ground plate, fine particulate that has not completely made it to the dust collector walls is deflected into the hopper. The ground plate also shields collected particulate from re-entraining during vortex reversal, acting as a barrier between the separation chamber and the collection hopper. This innovative design enables a compact dust collector to operate at high efficiency, even when installed horizontally.


 
 